Download Product Information Contact us

Home > Libraries > PIPELIQTRAN library examples

PIPELIQTRAN library examples

Power failure to a feed pump

This example represents the analysis of transients in a pipeline caused by power failure to the feed pump. The flowsheet is depicted below:

Chaudry_46 example for the PIPELIQTRAN library

The following figures illustrate the evolution of the total fluid height and the mass flow at the inlet of pipes "P2" and "P3":

Plot 1 for the Chaudry_46 example

Plot 2 for the Chaudry_46 example

Sequential start-up of two feed pumps

This example represents the sequential start-up of two feed pumps with the circuit full of water in a circulating water system.

The aim of this example was to check if the opening time of the discharge valves is adequate so that the pressures in the system do not exceed the tolerated limits.

The flowsheet is depicted below:

Naco example for the PIPELIQTRAN library

The following figures illustrate the evolution of the inlet and outlet pressure in the feed pumps, the mass flow across these pumps, and the actual rotor speed of the pumps:

Plot 1 for the Naco example

Plot 2 for the Naco example

Plot 3 for the Naco example

back...